Electro-Optics Simultaneous measurements of position and angular displacements. The system offers real time measurements of beam position and angular displacements as well as power display, with resolution down to 0.1 um for position and better than 20 microradions for angles.​Accuracy’s deviation is directly proportional to the deviation amount from center. For small deviations resolution values could be used.The system measures CW beams, and offers portable, fast and accurate beam alignment solution.

18 People watching this product now!

Description

AlignMeter USB

Electro-Optics Simultaneous measurements of position and angular displacements. 
The system offers real time measurements of beam position and angular displacements as well as power display, with resolution down to 0.1 um for position and better than 20 microradions for angles.

​Accuracy’s deviation is directly proportional to the deviation amount from center. For small deviations resolution values could be used.

The system measures CW beams, and offers portable, fast and accurate beam alignment solution.

An adaptor for connecting to an articulated arm knuckle is available: Knuckle Adaptor

AlignMeter-USB-pic

Specifications

Parameters Value (Standard) Value (optional)
PSD size  9 x 9 mm  4 x 4 mm 
Usable beam size range  50 μm to 8 mm  50 μm to 3 mm 
Update rate  Max. 150 Hz at 500 Hz digital filter  Max. 150 Hz at 500 Hz digital filter 
Spectral range  350 – 1100 nm  350 – 1100 nm 
Position measurement range  8 mm dia. circle max.  3 mm dia. circle max. 
Power range  10 μW – 10 mW with filters  10 μW – 10 mW with filters 
Power accuracy (*)  ±5%  ±5% 
Lens type  Plano convex achromat, A/R coated  Plano convex achromat, A/R coated 
Beam splitter  50:50 A:R coated, non-polarized  50:50 A:R coated, non-polarized 
Operating temperature  0° – 35° C  0° – 35° C 
Optional accessories  ND filters, Hood  ND filters, Hood 

(*) – To maintain full calibration accuracy, attenuating optical filter (ND) may be necessary for operation with beams greater than 1 mW per PSD @ 633 nm

Parameters AlignMeter 50 AlignMeter 100
Lens focal length  50 mm  100 mm 
Position resolution  Down to 0.1 μm at 50 Hz digital filter + averaging  Down to 0.1 μm at 50 Hz digital filter + averaging 
Position accuracy  ±15 μm edge-to-edge (±8μm)  ±15 μm edge-to-edge (±8μm) 
Angle measurement range  180 mRad (90 mRad)  80 mRad (40 mRad) 
Angle resolution  0.02 mRad (0.01 mRad)  0.01 mRad (0.006 mRad) 
Angle accuracy  0.5 mRad edge-to-edge (0.3 mRad)  0.25 mRad edge-to-edge (0.15 mRad) 
Weight  140 gr. excluding cables  180 gr. excluding cables 
Parameters AlignMeter 200

PSD size for position

4 x 4 mm for angle, 9×9 for position

Usable beam size range

50 μm to 3 mm

Update rate

Max. 150 Hz at 500 Hz digital filter

Spectral range

350 – 1100 nm (calibrated at visible 400-700 nm)

Position measurement range

3.5 mm dia. circle max.

Power range

10 μW – 10 mW with filters

Power accuracy (*)

±5%

Angle measurement range

17 mRad

Angle resolution

0.005 mRad (50 Hz Filter) – 0.0003 degrees

Position accuracy

±5 μm  edge to edge, ±1 μm  for small movements